Anton/Bauer LOGIC Series User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 23
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
- 11 -
RealTime Display Indications
When the battery is being charged no remaining runtime is displayed.
Remaining run time is calculated using the present available battery
capacity and a constantly updated accurate measurement of the
present load on the battery.
If no load is detected, or if the battery is removed from the charger
before any discharge load is applied, the default assumed power for
remaining run time calculations is 20 Watts.
When the battery determines that a load is attached, remaining run
time will be calculated based on that load and the time remaining will
be updated.
• The battery will “learn” this new load and retain that load information
in non-volatile memory. If the battery is removed from the camera it
will retain this information for 30 minutes or until it is returned to the
charger or sees a new load. After 30 minutes the battery will return to
the default load of 20 watts.
OVERCURRENT INDICATION
If the battery is subjected to a load that exceeds specifications all
status icons on the LCD will flash at a once per second rate. When
the over-load condition is removed, the display will return to normal.
When the battery is completely discharged the LCD will flash the 15
minute icon until the battery is returned to a charger.
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Comments to this Manuals

No comments